I began with the XONO, with my main aim being to correct the THD+N v. amplitude graphs from the previous tests. This time, the measurement was taken with standardized values for the input voltages (200 uV - 1mV for MC, and 600-5mV for MM) and capacitive loading (100 ohms for MC, and 47 kohms for MM).
Frequency response for the XONO MC input.
The Moving Magnet response was pretty much similar. Below are screenshots of these graphs.
The THD+N vs. frequency for the MC input looks just like the MC input.
The cross-talk is a bit different though. The values are about 10 dB lower in the MM.
IMD and idle channel noise for both the MC and MM inputs can be seen in the previous posts with screenshots. Next up tomorrow is the Steelhead.
No comments: